Experience effortless frozen tissue sectioning with our Semi-automatic Cryostat Microtome featuring a user-friendly touch screen interface. This innovative instrument combines precision and convenience, ensuring consistent, high-quality sections for rapid pathological assessments and research applications.
It is designed overall engineering and ergonomic concepts. All the components are processed by computer numerical control.
Retraction function prevents specimen damage from blade.
Total thickness calculation.
Low temperature refrigeration system with environment friendly refrigerant R404.
Adopt UV sterilize for 30 minutes every time.
Peltier specimen clamp refrigeration can be turn On or Off manually.
Two defrosting methods: manual and automatic.
The high prevision unit is enclosed outside the cryostat chamber to prevent it from thermal expansion and contraction, and keeps minimum maintenance requirement.
Artificial intelligent interface is easy to learn and operate.
Touch Screen and display all information including thickness, thickness sum, controlling time, temperature, time on/off and so on.
Sleep Function: after activating this function, the temperature in cryostat chamber can be kept between -1℃ and -10℃; after stopping this function, the temperature in freeze chamber will rise to working temperature within 30 minutes.
Control panel with locking function could avoid faulty operation.
Handwheel locking function.
Wide freezing shelf can load 17 specimen cassettes simultaneously, and two of them are equipped with peltier to meet different temperatures.
Environment requirement | Temperature Range | +15℃~+30℃ | |||||
Air Humidity | ≤60% | ||||||
Working pressure | (86~106)kPa | ||||||
Nominal Voltage | 220~240V AC/100~120V AC | ||||||
Normal Frequency | 50/60 Hz | ||||||
Powe | ≤1000VA | ||||||
Fuse | 8A/20A | ||||||
Safe Classify | Classify I - Type B | ||||||
Lowest freeze chamber Temperature | -35±2℃ | ||||||
Lowest freeze shelf Temperature | -45±5℃ | ||||||
Lowest temperature of peltier unit on freeze shelf | -55±5℃ | ||||||
Lowest temperature of peltier unit on specimen clamp | -50±5℃(Working time of peltier: 15 minutes) | ||||||
Electric coarse feed | Slow: 300µm/s±30µm/s Rapid: 900µm/s±30µm/s | ||||||
Section thickness range | 0 to 100µm 0 to 3µm, in 0.5µm increments 3 to 10µm, in 1µm increments 10 to 20µm, in 2µm increments 20 to 100µm, in 5µm increments | ||||||
Trimming thickness range | 0 to 600µm 0 to 50µm, in 5µm increments 50 to 100µm, in 10µm increments 100 to 600µm, in 50µm increments | ||||||
Retraction | 0~80µm, in 5µm increments | ||||||
Specimen feed | 24mm ±0.2mm | ||||||
Vertical stroke | 54mm±1mm | ||||||
Specimen Max | 35×35mm | ||||||
Repositioning of blade holder base(left-right) | 50±1mm | ||||||
Motorize cutting speed | 75~230mm/s ± 10% | ||||||
Dimension | Width | 715mm | |||||
Length | 765mm | ||||||
Height | 1230mm | ||||||
Weight | About 130kgs |